Sign In | Join Free | My infospaceinc.com
China Shanghai Anping Static Technology Co.,Ltd logo
Shanghai Anping Static Technology Co.,Ltd
Shanghai Anping Static Technology Co.,Ltd
Active Member

9 Years

Home > Anti Static Bar >

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar

Shanghai Anping Static Technology Co.,Ltd

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar

Brand Name : AP&T

Model Number : AP-AB1103

Certification : CE

Place of Origin : China

MOQ : 1 piece

Price : Negotiate

Payment Terms : T/T, Western Union, MoneyGram,PayPal,cash

Supply Ability : 1000 pieces per month

Delivery Time : 5 working days

Packaging Details : In cartons

Model No. : AP-AB1103

Working voltage : AC5600V(<1000mm);AC7000V(Length≥1m)

Power : 20W

Electrode : SUS

Ion balance : ≤|±150V|(AVE)

Decay time : ≤1.0S(working distance100mm)

Accessory : M4×20 screw bolt

Warranty : 1 Year

Function : Easy to remove high voltage static electricity

Product name : static neutralizing bar

Application : anti static eliminator for printing machine

Hv cable length : 2m

Contact Now

Bar Shape Static Eliminator AP-AB1103 AC Electroshock-proof Anti Static Bar

General

AP-AB1103 ion bar is the bar shape static eliminator developed by Shanghai Anping Static Technology Co.,Ltd.

AP - AB1103 ion bar generates positive and negative ion on emitter by AC high voltage and transfer the ion by pressed air to the object surface to be static removed. Thus neutralize the ion on the object surface and eliminate static efficiently and reliably. .

It is widely used in electronics, plastics, chemicals, printing, textile, optical and other industries.

Product Feature

(1)Bar shaped and cross over static eliminator

(2)Compact structure and elegant appearance

(3)Working under high voltage and micro current (μA level)

(4)Electroshock-proof function

(4)Stripe shaped notch on the back of the bar for user to fasten the bar

Specification

Model No. AP-AB1103
Working voltage AC5600V(<1000mm);AC7000V(Length≥1m)
Power 20W
Working way AC
Electrode SUS
Discharge structure Resistance coupling
Discharge range L*W*H(150mm→3000mm)*300mm*100mm
Working distance 30-150mm
Ion balance ≤|±150V|(AVE)
Decay time ≤1.0S(working distance100mm)
Working temperature 0°C - 50°C
Working humidity <70%
Dimension L*W*H(150mm→3000mm)*20.4mm*32mm
Bar material Flame retardant PVC,AL
Accessory M4×20 screw bolt
Power supply

AP-AY1505/ AP-AY2505(Length <1m):

AP-AY1502/ AP-AY2502(Length≥1m):

HV cable 2.5m(can do customize,Max10m)
Warranty 1 Year
Certificate CE

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar

Industry Application

Can be used in electronics, plastics, chemicals, printing, textile, optical and other industries.

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar

Test standard:ANSI/ESD.STM3.1,ANSI/ESD.SP3.3,SJ/T 11446—2013

Test Device:Trek157 static detector

Test Voltage:±1000V → ±100V attenuation

Test environment:Humidity 50±5%;Temperature23±3℃

Safety warning

1. Please read the instruction manual carefully before installing and using this equipment.

2. The entire set of equipment must be reliably grounded during use, otherwise it is easy to cause abnormal or even damage to the ion rod.

3. It is not suitable to use this equipment in the environment with> 70% humidity.

4. It is strictly forbidden to use this equipment in flammable and explosive environments.

5. Unauthorized disassembly of the product is strictly prohibited, and internal maintenance and repairs must be performed by professionals.

6. The product is strictly prohibited from touching water stains, otherwise an abnormality may occur, resulting in electric shock or fire.

7. Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire.

8. The product is specially designed for removing static electricity. Other uses are strictly prohibited. Any abnormal use may cause hidden troubles such as machine failure, electric shock and fire.

9. It is strictly forbidden to touch the electrode needle when it is energized, otherwise it may cause malfunction and electric shock accident.

10. The discharge needle is a sharp metal object, please use it carefully.

11. Before the product is powered on, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure to the product.

12. Please check the product power line / communication line regularly, and replace it immediately if it is damaged, otherwise it may cause problems such as leakage, poor communication and abnormal operation.


Product Tags:

Electroshock Proof Anti Static Bar

      

AC Anti Static Bar

      

Resistance Coupling Static Neutralizing Bar

      
Quality AP-AB1103 AC5600V Electroshock Proof Anti Static Bar for sale

AP-AB1103 AC5600V Electroshock Proof Anti Static Bar Images

Inquiry Cart 0